WLR meter

Description

The WLR meter has been developed by Pietro Fiorentini to offer to the users a dedicated product to complete the range of metering solutions.

It is a modular, inline system, providing real-time measurements of water content in a multiphase flow.

The sensor is a microwave quarter-wavelength coaxial resonator type, with a high pressure rating dielectric window exposed to the process. By scanning and defining the resonance frequency, the permittivity/conductivity of the fluid is calculated, and thus the water content.

The WLR meter can be supplied as stand alone configuration or integrated in a multiphase flow meter.

Features

  • Operating range: 0-100% GVF, 0-100% WLR
  • Size: from 2″ to 14″
  • Design pressure: up to 5.000 psi (345 bar)
  • Design temperature: up to 250 °F (121 °C)
  • Process connection: ANSI/API flanges or clamped hubs
  • Data Connectivity: serial RS-422/RS-485 single/redundant or Ethernet TCP/IP (Modbus)
  • Flow Electronic Transmitter:
    • Real Time controller
    • Electronics temperature -40° C / + 85° C
    • Power supply: 24VDC, or 110÷240 V 50÷60Hz
    • Power consumption: 20W
    • Enclosure for hazardous area
    • Weather protection: IP 66
    • Stainless steel or aluminum enclosure
    • With local display (as optional)
    • ATEX/IECEx certification Ex d IIB T3-T6 Ga
  • HMI: HMI for Windows